BEAUTY MACHINE

Perfectlaser W706 Professional Cold Plasma Device | Non-Surgical Skin Tightening, Acne & Hair Growth Treatment System

✅ NON-DESTRUCTIVE COLD PLASMA TECHNOLOGY
Utilizes Low Intensity Cold Atmospheric Plasma (LICAP) with Argon gas to generate therapeutic electric arcs without skin damage. This triggers skin renewal through ozone/oxygen activation and UV light emission (1-2mm penetration), providing pain-free treatments with zero downtime. Ideal for sensitive skin and large-area applications like full-face rejuvenation or scalp therapy.

✅ 8 INTERCHANGEABLE MEDICAL-GRADE PROBES (11 PC SET)
Modular system includes specialized tips: 1) Square Hyper Tip (wrinkles/texture), 2) Gas Roller (product absorption), 3) Nozzle Tip (acne/antibacterial), 4) Gas Needle (large areas), 5) Horn Tip (scalp/cellulite), 6) Diamond Needle (eyelid/neck lift), 7) Ceramic Tip (fungal/scar treatment), 8) Curved Nozzle (body firming). Tool-free swapping enables multi-condition protocols.

✅ SMART ERGONOMIC HANDLE WITH REAL-TIME CONTROL
Features R-Mode gas adjustment knob for precision plasma flow regulation, anti-slip grip for delicate zones (e.g., eye contour), and cold/thermal mode switch. LED status indicators ensure safe operation, while ceramic-bodied probes resist heat/corrosion for 500,000+ shot lifespan.

✅ CLINICAL-GRADE APPLICATIONS (30+ INDICATIONS)
Treats 30+ conditions: skin tightening, acne/scar reduction, hair growth stimulation, psoriasis/eczema management, wart/herpes removal, nail fungus, surgical scar revision, and non-healing wounds. Particularly effective for delicate areas (décolletage, eyelids) and intimate zones with no anesthesia required.

✅ 100W POWER & PROFESSIONAL WORKFLOW TOOLS
12.1″ touchscreen with visual probe selection guide and before/after gallery. Foldable HD display simplifies storage, while 110-220V compatibility supports global clinics. Compact design (40.4×31×18cm, 13kg) with hospital-grade hygiene protocols.

Perfectlaser W706 Professional Cold Plasma Device | Non-Surgical Skin Tightening, Acne & Hair Growth Treatment System

✅ NON-DESTRUCTIVE COLD PLASMA TECHNOLOGY
Utilizes Low Intensity Cold Atmospheric Plasma (LICAP) with Argon gas to generate therapeutic electric arcs without skin damage. This triggers skin renewal through ozone/oxygen activation and UV light emission (1-2mm penetration), providing pain-free treatments with zero downtime. Ideal for sensitive skin and large-area applications like full-face rejuvenation or scalp therapy.

✅ 8 INTERCHANGEABLE MEDICAL-GRADE PROBES (11 PC SET)
Modular system includes specialized tips: 1) Square Hyper Tip (wrinkles/texture), 2) Gas Roller (product absorption), 3) Nozzle Tip (acne/antibacterial), 4) Gas Needle (large areas), 5) Horn Tip (scalp/cellulite), 6) Diamond Needle (eyelid/neck lift), 7) Ceramic Tip (fungal/scar treatment), 8) Curved Nozzle (body firming). Tool-free swapping enables multi-condition protocols.

✅ SMART ERGONOMIC HANDLE WITH REAL-TIME CONTROL
Features R-Mode gas adjustment knob for precision plasma flow regulation, anti-slip grip for delicate zones (e.g., eye contour), and cold/thermal mode switch. LED status indicators ensure safe operation, while ceramic-bodied probes resist heat/corrosion for 500,000+ shot lifespan.

✅ CLINICAL-GRADE APPLICATIONS (30+ INDICATIONS)
Treats 30+ conditions: skin tightening, acne/scar reduction, hair growth stimulation, psoriasis/eczema management, wart/herpes removal, nail fungus, surgical scar revision, and non-healing wounds. Particularly effective for delicate areas (décolletage, eyelids) and intimate zones with no anesthesia required.

✅ 100W POWER & PROFESSIONAL WORKFLOW TOOLS
12.1″ touchscreen with visual probe selection guide and before/after gallery. Foldable HD display simplifies storage, while 110-220V compatibility supports global clinics. Compact design (40.4×31×18cm, 13kg) with hospital-grade hygiene protocols.

Parameter Specification
Technology Cold Atmospheric Plasma (CAP)
Gas Type Argon
Power Input 100W (AC 110-220V)
Probes 8 Types (11 pcs total)
Penetration Depth 1-2mm
Display 12.1″ Foldable Touchscreen
Net Weight 13kg
Dimensions 40.4×31×18cm (Net) / 40×35×57cm (Packaged)
Therapeutic Effects Antibacterial, Anti-inflammatory, Regenerative
YouTube video
Product Details

Clinical Performance & Solutions
The W706 revolutionizes non-invasive aesthetics with plasma-induced skin regeneration. Solves:

  • Skin Aging Concerns: Wrinkles, laxity, sun spots

  • Pathological Conditions: Acne, eczema, fungal infections

  • Sensitive Area Limitations: Eyelid bags, lip lines, hand rejuvenation

  • Chronic Disorders: Non-healing wounds, nail fungus, seborrheic eczema

Technology Workflow

  1. Gas Ionization: Argon plasma creates controlled electrical arcs

  2. Biological Activation: Releases ozone, oxygen species, and UV light

  3. Tissue Response: Stimulates collagen/elastin synthesis without epidermal damage

  4. Therapeutic Effects: Antibacterial action + accelerated cell turnover

Target Markets

  • Dermatology & Trichology Clinics

  • Medical Spas Offering “Lunchtime Facelifts”

  • Wound Care Centers

  • Integrative Wellness Facilities

Competitive Advantages

  • Zero Skin Damage: Unique di-CAP technology avoids thermal injury

  • Unlimited Shots: No consumable costs vs. laser cartridges

  • Multi-Specialty Use: From acne treatment to scalp restoration

  • Hygienic Design: Autoclavable ceramic probes

  • Instant Protocol Switching: Cold mode (sensitive skin) ↔ Thermal mode (deeper concerns)

Technical Specifications

Parameter Specification
Technology Cold Atmospheric Plasma (CAP)
Gas Type Argon
Power Input 100W (AC 110-220V)
Probes 8 Types (11 pcs total)
Penetration Depth 1-2mm
Display 12.1″ Foldable Touchscreen
Net Weight 13kg
Dimensions 40.4×31×18cm (Net) / 40×35×57cm (Packaged)
Therapeutic Effects Antibacterial, Anti-inflammatory, Regenerative

Get in Touch

Get in touch

Hello there! Kindly fill in the details of the machine and the questions that interest you, along with your contact information. Rest assured, a dedicated salesperson will get in touch with you promptly. Thank you.

Perfectlaser

Request Documentation